Assembly and Installation
FLOWSIC100 Flare · Operating Instructions · 8013344/11L2/V 2-5/2018-10 · © SICK Engineering GmbH
113
Su
bj
ect
to
ch
an
ge
with
ou
t n
otic
e
Assembly
Loosen fastening screws (1) on blind flange (2) and remove the blind flange.
Position the sender/receiver unit (3) on the ball valve (4) and screw on with fastening
screws (1).
Remove cotter pins (6) from guide rods (7) and loosen both fastening nuts (8).
Open the ball valve (4).
Carefully insert the sender/receiver unit into the ball valve and nozzle to stop and fasten
with nut (8).
Attach cotter pins (6) to guide rods (7).
Check all process connections for tightness.
Installing the nozzle isolation set
To prevent danger of galvanic corrosion a "Nozzle isolation set" can be used (option). For
installation see instruction in