Figure 99: Configuration dialog of the MSG block
12. Configure the following parameters in the
Configuration
tab:
°
Service Type
: Set Attributes Single (
°
Instance
: 1 (as only one device is connected to the controller)
°
Class
: 23(h) (position sensor object,
)
°
Attribute
: 13(h) (Preset Value,
)
°
Source Element
: PRESET_Value
°
Source Length
: 4
NOTE
PRESET_Value is the fourth variable created. The preset value is taken from this
when the example program is executed and written to attribute 13h of the position
sensor object.
13. Open the Communication tab.
Figure 100: Communication tab
14. Next to the
Path
field, click the
Browse...
button.
✓
The
Message Path Browser
dialog opens.
15. Select the connected encoder.
CONFIGURATION USING A PLC
5
8014213/1EF3/2021-12-08 | SICK
O P E R A T I N G I N S T R U C T I O N S | AFS/AFM60 EtherNet/IP
91