17
8012426/YWL2/3-0/2016-08| SICK
O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER SP100
Subject to change without notice
PRODUCT DESCRIPTION
2
Type code
A type code identifies the special version of the sender/receiver unit:
Sender/receiver unit:
DHSP-T X X X X NNXX
Maximum permissible gas temperature:
- 2:
220 °C
-- 4:
400 °C (250 °C in version for internal duct pressure up to +200 kPa)
Probe material
- V:
Stainless steel
- H:
Hastelloy
- M:
Hastelloy probe + stainless steel protective tube
- S:
SS/HS probe + SS Da88 protective tube
- C:
Stainless steel probe + protective tube, plastic-coated
- X:
Special version
Measuring probe nominal length (NL)
- 1:
435 mm
- 2:
735 mm
- 3:
1035 mm
- 4:
1335 mm
- 5:
1635 mm
- 6:
1835 mm
- 7:
2085 mm
- X:
Special version
Flange version
- 1:
Reference circle k100
- 2:
Reference circle k150
- 3:
Reference circle k191
- X:
Special version
Ex certification
- NNXX: Without