Figure 21: Double safety-related zone
Figure 22: Observation window
Setting
Description
Behavior of digital
output
The “Switching behavior” setting can be used to manually select whether
the output should relate to the Double safety-related Zone (
) or Observation window (
When the switching behavior is changed, the values set for switching
point 1 and switching point 2 are automatically swapped by the device.
Switching point 1
•
With the “Switching point 1” setting, the first of the two switching
points of the switching window can be set manually in millimeters.
•
The first of the two switching points can be taught in for the Switching
window (
Window mode
) switching mode using the “Switching point 1”
teach method.
For
Double safety-related zone
(
), “Switching point 1”
must be taught in first, for
Observation window
),
“Switching point 2” must be taught in first to avoid switching the behavior
twice during teach-in.
COMMISSIONING AND CONFIGURATION
7
8027663//2022-08-04 | SICK
O P E R A T I N G I N S T R U C T I O N S | DT35S
33
Subject to change without notice