14.5
Notes on PROFINET
14.5.1
Basic information on PROFINET
SICK recommends familiarizing yourself with the basic information described in
the planning guidelines and commissioning guidelines of the PI user organization
(PROFIBUS & PROFINET International, homepage:
).
These guidelines can be found in the "Downloads" area at:
•
14.5.2
General notes on PROFINET wiring
The wires of the signal cables must be wrapped in pairs (twisted pairs), and the cables
must comply with at least CAT5 according to ISO/IEC 11801 Edition 2.0. Class D. The
signal lines must also be shielded and grounded.
SICK recommends using components certified by PROFINET.
More detailed information can be found in the “PROFINET Cabling and Interconnection
Technology” Installation Guide.
You can find the document in the “Downloads” area at:
•
14.5.3
PROFINET Conformance Class
The device complies with PROFINET Conformance Class B (CC-B) and supports the
properties defined within.
Further information on the PROFINET Conformance Classes can be found in the docu‐
ment of the PI user organization (PROFIBUS and PROFINET International).
You can find the document in the “Downloads” area at:
•
14.5.4
General requirements on a switch suitable for PROFINET applications
For PROFINET Conformance Class B and C (CC-B / CC-C), use only a PROFINET-certified
switch that can be configured as a PROFINET device.
For further information, refer to the commissioning guidelines of the PI “Installation
Guideline PROFINET Part 2: Network Components”.
You can find the document in the “Downloads” area under:
•
14.5.5
Notes on installing the SICK bar code scanner into a PROFINET network
For 1-port devices, these include:
•
LLDP (neighborhood detection)
1)
•
I&M 0-4 (device identification)
1)
•
Device exchange by topology check
1)
•
16 bit digital “status word” for reading gate result
•
16 bit digital “control word” for controlling the device via PLC
•
Heartbeat (for checking communication)
•
GSD file for configuring the device using modules via the PLC
1)
For 2-port devices, these include:
1)
Properties of the CC-B
ANNEX
14
8017842/19XD/2021-11-19 | SICK
O P E R A T I N G I N S T R U C T I O N S | CLV61x DualPort (PROFINET)
77
Subject to change without notice