10.4
Disassembly
Dismantling the device
1.
Switch off the supply voltage to the device.
2.
Disconnect all connecting cables on the device.
3.
To replace the device, mark the position and orientation of the device on the
bracket or surrounding area.
4.
Remove the device from the bracket.
5.
If available, remove the memory card (optional) with the saved parameter set from
the defective device. To do this, carefully open the black rubber cover and press
lightly on the memory card to unlock it.
10.5
Returns
b
Only send in devices after consulting with SICK Service.
b
The device must be sent in the original packaging or an equivalent padded pack‐
aging.
NOTE
Optional memory card
•
Check whether there is a memory card in the card slot of the device. If yes, remove
the memory card from the faulty device in
de-energized state
.
•
Do not send in the memory card!
NOTE
To enable efficient processing and allow us to determine the cause quickly, please
include the following when making a return:
•
Details of the contact person
•
Description of the application
•
Description of the fault that occurred
10.6
Device exchange with transmission of the current configuration data
NOTE
Backup concept with computer: If the parameter set of the defective device is saved,
the parameter set can be transferred manually to the replacement device. For possible
alternatives due to optional equipment, see the following section.
1.
Check that the replacement device of the same type (repaired or new device) is
de-energized.
2.
Mount and align the replacement device (
). When doing
so, note the previously applied markings on the bracket or surroundings (
).
3.
Connect the connecting cables to the replacement device.
4.
Switch on the supply voltage for the device. The device starts with its previous
settings (new device: defaults).