Display
Color
Behavior
LED
Device status
P2 LNK
Green
O
Device connected to active network, e.g.
with
an Ethernet switch (switched-on)
P2 ACT
Orange
Ö
LED flickers.
Device is sending or receiving data.
o
= LED off,
O
= LED is lit,
Ö
= LED flashes or flickers.
1)
SF = System Failure.
2)
BF = Bus Failure.
8.1.2
Operating options
The device can be configured according to application in the following manner:
■
Locally at the device with the SOPAS ET configuration software. Backup of the
parameter set as a configuration file on the computer using SOPAS ET. Access to
the device via AUX interface (Ethernet or USB, depending on type).
■
As an alternative to the SOPAS ET configuration software, command strings are
available, upon which the operator interface of the configuration software is also
based. These are also for the triggering of device functions (e.g. reading). Docu‐
ments on the command strings can be obtained from SICK on request.
■
Centrally through the PROFINET controller. This is carried out via PROFINET using
GSD parameterization. Backup of the parameter set as a configuration file in the
PROFINET controller. Each time PROFINET is restarted, the device is reconfigured.
NOTE
The procedure for incorporating the device into the PROFINET controller (PLC) and
for central parameterization using the PROFINET controller is described in the supple‐
mentary information document “CLV61x Dual Port (PROFINET) fixed mount bar code
scanner” in English (part no. 8017978) and German (item no. 8017977).
The supplementary information can be found under “Documentation” on the online
product page at:
•
The SOPAS ET configuration software is used for device diagnostics in case of a fault.
The device operates fully automatically when operational.
OPERATION
8
8017842/19XD/2021-11-19 | SICK
O P E R A T I N G I N S T R U C T I O N S | CLV61x DualPort (PROFINET)
55