NOTICE
Damage to device through improper mounting!
To avoid damage during mounting and subsequent operation of the device, observe the
following:
•
Mount the vibration damper horizontally above or below the device.
•
Only use the screws provided.
•
Allow a working distance of at least 25 mm in all axis directions of the device. This
is particularly important when the device is installed at an angle.
•
To ensure strain relief, select an appropriate length for the connecting cables
based on the working distance.
Figure 20: Mounting with mounting bracket: Taking into account the working distance.
Observe the following during operation:
NOTICE
To avoid damage to the device during operation, observe the following:
•
The ground traveled upon is in good condition, e.g., free of large expansion joints
and potholes.
•
Recommendation for mounting of the vibration damper by the customer: To pre‐
vent the mounting screws from loosening, wet them with a thread-locking screw,
preferably LOCTITE 268.
•
Forklift truck applications: Ensure appropriate driving behavior when lowering the
forks, e.g., do not drive with the fork lowered, gently lift the load
•
Recommendation: Use a soft drop system.
NOTICE
Device damage due to lack of maintenance of the mounting brackets!
Mounting brackets with integrated vibration and shock absorption are subject to wear
and tear under heavier loads. The mounting brackets must therefore be assessed
and maintained on a regular basis. The exchange interval is application-specific and
depends on the level of exposure to vibrations and shocks.
5
MOUNTING
38
O P E R A T I N G I N S T R U C T I O N S | CLV61x DualPort (PROFINET)
8017842/19XD/2021-11-19 | SICK
Subject to change without notice