Maximum tightening torque: 2.5 Nm
Screw-in depth of the blind tapped holes
see "Mechanics/Electronics", page 66
in the
technical data.
1.
Prepare the base for mounting the bracket of the device,
.
2.
Place the object with bar code at the intended reading point of the device in the
viewing range of the device (no conveying movement).
3.
Align device with the bar code by eye. When doing so, be aware of the following:
–
For devices with a front viewing window: The rear of the device with the laser
warning label faces the viewer and is aligned approximately parallel to the bar
code surface.
–
For devices with a side viewing window: The side panel with the LEDs faces
the viewer and is aligned almost parallel to the bar code surface.
–
During reading, note the reading angle that occurs
4.
Mount the device bracket onto the base.
5.
Screw suitable screws through the bracket into the blind tapped hole of the device.
Tighten the screws lightly for the time being.
6.
Adjust the device,
see "Adjusting the device for operational use", page 51
7.
After adjustment, tighten the screws. Do not exceed the maximum tightening
torque.
5.5
Mounting with shock mounts (optional)
In application areas with severe vibrations or shocks to the device, mount the device in
conjunction with a suitable vibration damper. Faults are caused by vibrations, shakes
or abrupt changes in directions, e.g., when the device is mounted on a manned forklift
truck.
You can find suitable SICK mounting brackets with integrated vibration and shock
damping (absorbing elements) on the product page at:
•
Figure 16: Device with mounting
bracket (top bracket)
Figure 17: Device with mounting
bracket (bottom bracket)
Permissible mounting variants
The following two mounting variants using the SICK mounting bracket part no.
2042799 with integrated vibration and shock damping are permissible for line scan‐
ners (horizontal scan line):
1.
Horizontal mounting bracket mounted above the device (suspended device)
5
MOUNTING
36