5.
Depending on the selected configuration type, proceed as follows:
–
Central configuration via GSD parameterization: When the PROFINET is
restarted, the PROFINET controller automatically parameterizes the device.
–
Local automated configuration for device variants with an optional memory
card: The replacement device automatically transfers the saved parameter
set from the memory card into its permanent memory.
–
Local, manual configuration via SOPAS ET: Transfer the configuration stored
on the computer to the device via download (via USB or Ethernet, depending
on the type). Permanently save the configuration in the device.
NOTE
For further details see the supplementary information “CLV61x Dual Port (PROFINET)
bar code scanner” in English (article no. 8017978) and German (item no. 8017977).
The supplementary information can be found under "Documentation" on the online
product page at:
•
If automated PN name assignment for the device is configured and activated in the
PROFINET controller, the following conditions apply:
•
Central configuration: The entire permanently stored parameter set of the new
device being installed must be set to
default
(same as the state of a new device
upon delivery).
•
Local configuration: At least the “PN Name” field in the device’s parameter set
must be empty.
The device then automatically obtains the required PN names from the PROFINET
controller when the supply voltage is switched on.