NOTICE
•
Never connect a powered encoder interface unit to a camera.
•
Never connect signal levels that exceed the input specification to the encoder
inputs.
Failure to follow these rules can damage the camera.
NOTE
The function of the camera is not tested and guaranteed for Power I/O cables longer
than 10 meters.
NOTE
Use only shielded cables. The shield has to be connected at both ends of the cable.
There are two connectors on the back of the camera: Gigabit Ethernet (GigE) and Power
I/O (
To prepare the camera for operation, do as follows:
1.
Remove the protection caps that cover the connections for Gigabit Ethernet (GigE)
and Power I/O.
2.
Connect the Ethernet cable to the GigE connector on the camera. Connect the
other end of the Ethernet cable to the Network Interface Card (NIC) in the PC.
3.
Connect the connecting module to the Power I/O connector on the camera.
4.
Connect the unpowered voltage supply to the connecting module.
5.
Switch on the power to the system.
For more information on how to connect I/O signals to the camera,
.
7.5
Electrical connections
There are two connectors and four LEDs on the backplate of Ruler3000.
2
1
Figure 20: Backplate of the Ruler3000 device
1
Connector Gigabit Ethernet (GigE): M12, 8-pin female, X-coded
2
Connector Power I/O: M12, 17-pin male
7
ELECTRICAL INSTALLATION
34
O P E R A T I N G I N S T R U C T I O N S | Ruler3000
8026049//2021-04 | SICK
Subject to change without notice