outdoorScan3 Core I/O
Input frequency (max.
switching sequence when
used as control input)
≤ 20 Hz
Sampling time
4 ms
Response time at EDM after
switching on OSSDs (when
used as EDM input)
300 ms
Actuating duration of control
switch for reset (when used
as reset input)
60 ms to 30 s
Actuating duration of switch
for sleep mode (when used
as sleep mode input)
≥ 120 ms
1)
The power supply unit must be able to jumper a brief power failure of 20 ms as specified in
IEC 60204-1. Suitable power supply units are available as accessories from SICK.
2)
The voltage level must not fall below the specified minimum voltage.
3)
In the event of a fault (interruption of the 0 V cable), the specified leak current at most flows in the OSSD
cable. The downstream control element must detect this state as the OFF state.
Mechanical data
Table 29: Mechanical data
outdoorScan3 Core I/O
Dimensions (W × H × D)
112 mm × 135.1 mm × 111.1 mm
Weight (including system
plug)
1.15 kg
Housing material
Aluminum
Housing color
RAL 9005 (black) and RAL 2004 (pure orange)
Optics cover material
Polycarbonate
Optics cover surface
Outside with scratch-resistant coating
Ambient data
Table 30: Ambient data
outdoorScan3 Core I/O
Enclosure rating
1)
IP65 (IEC 60529)
Housing type
3R (UL 50E)
Ambient light immunity
Halogen light
2)
≤ 12000 lx (IEC 61496-3)
Sunlight
2)
≤ 40,000 lx (IEC 61496-3)
Ambient operating tempera‐
ture
–25 °C to 50 °C
3)
Storage temperature
–25 °C to 70 °C
Air humidity
≤ 95%, non-condensing
4)
Height above sea level during
operation
≤ 2300 m
Vibration resistance
5)
TECHNICAL DATA
13
8023152/1G5N/2022-06-28 | SICK
O P E R A T I N G I N S T R U C T I O N S | outdoorScan3 Core I/O
135