Sleep mode
If you activate this option, the safety laser scanner changes to the sleep mode as soon
as the input conditions for this monitoring case exist.
7.10.3
Input condition
For each monitoring case, choose the input conditions for which the monitoring case
will be activated.
b
Activate the combination of inputs for each monitoring case.
✓
The relevant monitoring case is activated for exactly this combination.
✓
Combinations which are invalid or already assigned are marked.
Complementary information
The
Generate input conditions
function allows you to automatically assign input conditions
to monitoring cases.
7.10.4
Cut-off paths
You can create cut-off paths and define the outputs switched by the cut-off paths.
(Example: the protective fields switch the OSSD pair, the warning fields switch a univer‐
sal output.)
You need a cut-off path for every field in a field set. If the field sets have different sizes,
use the field set with the most fields as a guide.
Creating cut-off path and entering a name
1.
Create a cut-off path for every field in the largest field set.
2.
Enter a descriptive name for each cut-off path.
Assigning an OSSD pair
b
Place a check in the box for the OSSD pair.
✓
The OSSD pair is assigned to the cut-off path.
Assigning unsafe outputs
b
Place a check in the box for the universal output(s).
✓
The universal output is assigned to the cut-off path.
7.10.5
Assigning field sets
Assigning a field set to a monitoring case
The field sets that have been created are listed in the
Field sets
area.
1.
Create cut-off paths,
.
2.
Drag the field set onto the monitoring case.
✓
The fields in a field set are arranged as they were drawn in the field editor (for
example protective field, warning field, warning field).
Deleting the assignment of a field set from the monitoring case
b
Drag the field set from the monitoring case table onto the trash-can icon.
✓
The field set is removed from the relevant monitoring case.
7
CONFIGURATION
100
O P E R A T I N G I N S T R U C T I O N S | outdoorScan3 Core I/O
8023152/1G5N/2022-06-28 | SICK