outdoorScan3 Core I/O
Standards
•
IEC 60068-2-6
•
IEC 60068-2-64
•
IEC 60721-3-5
•
IEC TR 60721-4-3
•
IEC 61496-1
•
IEC 61496-3
Class
•
5M1 (IEC 60721-3-5)
•
3M4 (IEC TR 60721-4-3)
Sinusoidal vibrations
•
50 m/s², 0.35 mm, 10 Hz … 150 Hz
•
5 m/s², 1.5 mm, 5 Hz … 200 Hz
•
10 m/s², 3.5 mm, 5 Hz … 150 Hz
Noise vibrations
•
0.5 m²/s³, 5 Hz … 200 Hz
•
0.1 m²/s³, 200 Hz … 500 Hz
Shock resistance
5)
Standards
•
IEC 60068-2-27
•
IEC 60721-3-5
•
IEC TR 60721-4-3
•
IEC 61496-1
•
IEC 61496-3
Class
•
5M1 (IEC 60721-3-5)
•
3M4 (IEC TR 60721-4-3)
Single shock
50 m/s², 11 ms
Continuous shock
•
100 m/s², 16 ms
•
150 m/s², 6 ms
EMC
In accordance with IEC 61496-1, IEC 61000-6-2, and
IEC 61000-6-4
1)
The specified enclosure rating is only valid if the safety laser scanner is closed, the system plug is
mounted, and all of the M12 plug connectors of the safety laser scanner have been closed using a cable
plug connector or using a protective cap.
2)
Values outside specification can prematurely age the device. Values outside specification can affect the
safety laser scanner. This may have a negative impact on the availability of the machine. That is to say,
the safety laser scanner switches off the machine even though there are no people in the protective field.
3)
The temperature of the device must be at least –10 °C when switched on. At lower temperatures the
device must be warmed up before it is switched on.
4)
IEC 61496-1, no. 4.3.1 and no. 5.4.2, IEC 61496-3, no. 4.3.1 and no. 5.4.2. Condensation has an
influence on normal operation.
5)
In direct mounting.
Miscellaneous data
Table 31: Miscellaneous data
outdoorScan3 Core I/O
Wavelength
845 nm
Detectable remission
1.8% to several 1,000%
Maximum uniform contami‐
nation of the optics cover
without reducing the detec‐
tion capability
1)
30%
Area where detection capabil‐
ity is restricted
≤ 50 mm
2)
Light spot size
3)
Devices with a max. protective field range of 4.0 m
13
TECHNICAL DATA
136
O P E R A T I N G I N S T R U C T I O N S | outdoorScan3 Core I/O
8023152/1G5N/2022-06-28 | SICK
Subject to change without notice