Safety-related parameters
Table 26: Safety-related parameters
outdoorScan3 Core I/O
Type
Type 3 (IEC 61496)
Safety integrity level
SIL 2 (IEC 61508)
SIL claim limit
SILCL 2 (IEC 62061)
Category
Category 3 (ISO 13849-1)
Performance level
PL d (ISO 13849-1)
Performance class SRS/
SRSS
Performance class D (IEC/TS 62998)
PFH
D
(mean probability of a
dangerous failure per hour)
8 × 10
–8
T
M
(mission time)
20 years (ISO 13849-1)
Safe status when a fault
occurs
At least one OSSD is in the OFF state.
Interfaces
Table 27: Interfaces
outdoorScan3 Core I/O
1
Automated restart of OSSDs
after
2 s to 60 s (configurable)
Voltage supply
Connection type
Male connector, M12, 8-pin, A-coding (collective male connec‐
tor for voltage supply and inputs and outputs)
Length of cable (power supply unit tolerance ± 5%)
Length of cable with wire
cross-section 0.25 mm
²
≤ 35 m
Local inputs and outputs
Connection type
Male connector, M12, 8-pin, A-coding (collective male connec‐
tor for voltage supply and inputs and outputs)
Length of cable with wire
cross-section 0.25 mm²
≤ 35 m
Configuration and diagnostic interface
Type of interface
USB 2.0
Connection type
USB 2.0 mini-B (female connector)
Transmission rate
≤ 12 Mbit/s
Length of cable
≤ 5 m
Electrical data
Table 28: Electrical data
outdoorScan3 Core I/O
Operating data
Protection class
III (IEC 61140)
Supply voltage V
S
24 V DC (16.8 V to 30 V DC) (SELV/PELV)
1)
Residual ripple
± 5%
2)
Start-up current at 24 V
≤ 3 A
TECHNICAL DATA
13
8023152/1G5N/2022-06-28 | SICK
O P E R A T I N G I N S T R U C T I O N S | outdoorScan3 Core I/O
133