Display
Device or configura‐
tion
Meaning
Configuration with
restart interlock
Protective field is clear, reset can take place.
Configuration with
restart interlock
Reset button pressed Safety output in the OFF
state.
Configuration with
restart interlock
Reset button pressed Safety output in the ON
state.
Configuration with
automated restart
after a time
Protective field is clear, configured time to
restart expires.
Configuration with at
least one warning field
Warning field interrupted (left column: num‐
ber of interrupted warning fields, right col‐
umn: number of warning fields in the current
monitoring case).
Display flashes
All devices and config‐
urations
Fault. All safety outputs in the OFF state. Addi‐
tional information:
.
Display flashes
All devices and config‐
urations
Contamination warning. Check the optics cover
for damage. Clean the optics cover.
Display flashes
All devices and config‐
urations
Contamination error. All safety outputs in the
OFF state. Check the optics cover for damage.
Clean the optics cover.
Display flashes
All devices and config‐
urations
Dazzle warning. Check whether the safety laser
scanner is being dazzled by an external light
source in the scan plane, e.g., sun, halogen
light, infrared light source. Remove or cover the
light source.
Display flashes
All devices and config‐
urations
Dazzle error. The associated safety outputs are
in the OFF state. Check whether the safety
laser scanner is being dazzled by an external
light source in the scan plane, e.g., sun, hal‐
ogen light, infrared light source. Remove or
cover the light source.
9
OPERATION
114
O P E R A T I N G I N S T R U C T I O N S | outdoorScan3 Core I/O
8023152/1G5N/2022-06-28 | SICK
Subject to change without notice