4
GETTING STARTED
66
8024172/V3-0/2021-01|SICK
Oper at i ng i ns t r uc t i ons | LABEL CHECKER P6XX
Subject to change without prior notice.
5.
Place the search area region shape on the desired region of interest.
6.
Adjust the Speed/Robustness parameters and select the optimal locator
detection. Select from the six Speed/Robustness parameter options in order to
achieve the best results.
Options 1 and 2 (speed) are faster than 3 to 6 (robustness), but with a higher
chance of unfavorable results.
7.
Adjust the maximum rotation. Increase the rotation value, it allows the locator to
search in a different rotation (+/- 180°), of the shape. But if set with no tolerance
(+/- 0°- 1°) then there is a higher chance for unfavorable results.
Always leave a favorable (robust) degree of freedom.
Maximum rotation
Minimum match
MATCH
Favorable
Unfavorable
Figure 38 Favorable and unfavorable results of shape location