Operating instructions | LABEL CHECKER P6XX
Please be informed that having enough illumination leads to lower value,
resulting to shorter exposure time. Higher value can cause blurring, if the object
is moving during exposition.
If the object is moving, we recommend using lower value, then compensate the
brightness by increasing Gain.
If the exposure time is too short, the image will be underexposed, i.e. generally
dark with low contrast between the part and its features.
If the exposure time is too long, then large sections of the image will appear white
and washed out.
5.
Adjust the FOV width and FOV height.
Unadjusted FOV
Adjusted FOV
We highly recommend reducing the field of view (FOV) height & width to the
lowest required rate to achieve faster imaging process.
The size of the field of view significantly affects the evaluation speed.
6.
Enable these functions to change the image’s orientation.
Flip image horizontally
Flip image vertically