![SICK 1086947 Operating Instructions Manual Download Page 57](http://html.mh-extra.com/html/sick/1086947/1086947_operating-instructions-manual_1264314057.webp)
GETTING STARTED…
4
57
8024172/V3-0/2021-01
Subject to change without prior notice.
Operating instructions | LABEL CHECKER P6XX
Scale factor
Sets the scale interval in order to teach the size. The points on each end of the bar reflect
a scale factor. In order to favorably find a taught object in the acquired image, taught
object must be set more or less bigger or smaller.
Defines how much the shape can be smaller and bigger compared to reference shape. By
setting both values to 1, the algorithm searches for exactly the same size of shape.
Decreasing the first value to 0.5 will force the algorithm to look even for a half-sized
shape. Increasing the second value to 2 will also look for a double-sized shape. This
setting has a great impact on the search speed.
Object locator timeout
Sets the allowed maximum time to search for the locator.
Advanced setup
The parameters for advanced setup determine the contrast of what the model points
must have. The contrast is a measure for local gray value differences, between object &
the background, and between different parts of the object.
Contrast low - the lowest value used for threshold
Contrast hysteresis - high threshold value; where, low + hysteresis
Minimum segment length - sets the minimum length of the found components.
Timeout - determines the maximum time that the locator object tries to find the shape.