Dear Customer,

congratulations for choosing a Syncra HF. This pump is ideal for many aquarium and 

pond  applications  including:  waterfalls,  small  streams,  powering  external  filters  or 

gravity filters, UV sterilizers, professional filtration systems, as well as return pumps 

or in sumps for large aquariums. Syncra HF have leading edge technology with a user 

friendly design. The pump comes equipped with threaded inlet and outlet which can be connected 

to different standard fittings and accessories available on the market.

IMPORTANT SAFETY INSTRUCTIONS

Syncra HF is made in conformity with the national and international security laws. Please read 

carefully and save the following instructions to use in the best way your Syncra HF.

1) Always isolate the pump from the mains electricity before installing or carrying out any 

maintenance. Power to the pump must be supplied through a Residual Current Device (RCD) 

with a rated residual operating current not exceeding 30mA

2) The pump can work “Wet & Dry”, in or out of water.

3) Before connecting the pump to the electricity supply, check there are any damages on cord 

or plug.

4) The pump has a type Z cable link. The cable and the plug cannot be substituted or repaired; in 

case of damage of them replace the entire pump. 

5) 

ATTENTION:

 do not operate any appliance if it has a damaged cord or plug, if it is malfunctioning, 

or if it has been dropped or damaged in any way.

6) The pump must not be used without water  otherwise non reparaible damage may accure 

to the motor.

7) The pump can be used in liquids or in environment with a temperature not higher than 35° C 

/ 95° F.

8) Do not use the pump for uses different to those for which it has been projected as, i.e. in 

bathroom or similar applications.

9) Avoid to use the pump with corrosive and abrasive liquids.

10) The pump cannot be used by people with handicaps or by children if they are not supervised by 

a person responsible for their safety.

11) To avoid that accidental drips wet the plug or the socket, make a loop with the cord under the 

socket level 

(Pic. A)

12) Avoid to take the pump by the cord during the installation or maintenance.

13) The pump can be used only in the above mentioned applications and it is only for internal use.

14) If the pump or the filter is supplied with a cable 10 metres long, or a cable more than 6 feet 

long for the American type (USA), these appliances are  intended for outdoor use as required by 

international standards.

USE AND MAINTENANCE

Syncra HF pumps are designed favoring the almost total dismantling of its components, to 

facilitate proper use and maintenance and ensure a long life. Below is the list of the individual 

parts and spare parts 

(Pic. 2)

:

1 Completely submergible motor body

   insulated with bi-component resin

2 Noiseless and wear-proof rotor with hub impeller

3 O-ring + threaded volute 1” Gas (Mod. 10.0),

   1½” Gas (Mod. 12.0 - 16.0)

4 Volute tightening screws (4 pcs)

5 Rear pump cover

INSTALLATION

To install the Syncra HF proceed as follows:

- Connect the joint to the pump outtake to which you can Connect the hose with the appropriate 

diameter.

- Place the pump in an area of the pond, easily accessible for the maintenance operations.

- The pump can work horizontally and vertically.

If the pump is used sumersed and not in line, it must be always fully submersed (Pic. 3)

.

- Unwind the supply cable where it can be safe from any kind of damage.

6 Pre-filter

7 O-ring + stepped joint D25 mm and

   D30 mm with female thread 1” GAS mod. 10.0

8 O-ring + joint D38 mm

   with female thread 1½” GAS mod. 12.0 - 16.0

9 Mounting base ( Pond version)

10 Antivibration rubbers ( Aquatic version)

EN 

- Connect the plug to a power supply socket with the same voltage as the voltage indicated on 

the technical data label.

IN LINE APPLICATIONS

It is recommended to place the pump in spaces where there is a proper ventilation and the pump is 

not directly exposed to heat sources.

Place the pump so as to prevent too long idraulic pipings, which would reduce its performance.

Do not position the pump above the water level because it is not self-priming and the risk of the pump 

to run dry,  or of invisible air bubbles creating a vacum area is very high. Damages which are caused 

by the pump running dry are excluded from warranty. To maximize the pump’s efficiency, choose a 

straight inlet tube to be connected to bows or elbows 

(Pic. 4)

.

We suggest to use Inlet and outlet tubes with diameter egual or bigger than the diameter of the 

treathed pipe included 

(Pic. 5)

.

Do not use the pump leaving the outlet totally closed. A minimum water flow is necessary to keep 

the inner motor refrigerated and not running dry 

(Pic. 6)

.

MAINTENANCE

Syncra HF needs simple but necessary periodical maintenance for its correct and safe operation. 

Before starting first unplug the device from the socket and strictly comply with the safety instructions 

and the following procedure:

Remove the entire pump from the pond or from the tank

Disconnect the base 

(9)

. Pond Version

Disconnect the pre-filter 

(6)

 gently pressing on the flaps on the sides, separate the volute 

(3)

 from 

the pump 

(1)

 removing the screws 

(4)

, rinse everything with fresh water.

Remove the entire rotor 

(2)

 and rinse it with fresh water, using soap or vinegar and a soft toothbrush 

to remove possible calcifications.

Check and clean the rotor housing in the motor body 

(1)

, the recirculation system and the lower 

bushing with fresh water.

Perform the mounting operation as follows:

Insert the O-ring 

(a)

 in the housing inside the pump’s body 

(1)

.

Insert the O-ring 

(b)

 in the housing on the external holed disc of the rotor 

(2)

.

Insert the rotor 

(2)

 in the pump’s  body housing 

(1)

 checking that the O-ring 

(2)

 is correctly 

positioned in the housing of the pump body 

(1)

 to allow the correct centering of the rotor.

Insert the O-ring 

(c)

 in the external housing of the body 

(1)

.

Assembly the volute 

(3)

 to the body 

(1)

 pushing it in place and tighten the screws 

(4)

.

Assembly the pre-filter 

(6)

.

Assembly the base 

(9)

, put the pump in its original position and connect it to the power supply.

IMPORTANT:

 The pump is equipped with a thermal device and an electronic motor protection. In 

case of  malfunction which causes the locking of the rotor (due to excessive dirt or other) or operating 

without water, the pump, after 20 attempts, it stops automatically. In this case you must unplug the 

pump, check the water level and if the rotor is dirty. After maitenance operations, as per the above 

instructions, you can plug the pump on to restart it. It may take up to a ‘time If the thermal device has 

switched on.

ATTENTION:

 do not underestimate the power of the magnet. If you slightly loose the grip and the 

axis hits the rear bearing, the risk to damage the bearing is very high. A damage axis and bearing 

causes high reparation costs.

SPECIAL MAINTENANCE AND REPLACING GROUP ROTOR

Remove the complete rotor 

(2 - Pic. I)

 from the pumps’ body. Insert the hook inside the rotor’s house 

(Pic. II)

, snap the ceramic bearing located in the end side of the internal pump’s body 

(Pic. III)

 and 

pull out using a little strenght.

Rinse with fresh water and vinegar the internal sides of the pump and locate the new ceramic bearing 

at the beginning of the rotor’s house. 

(Pic. IV)

. Insert the O-ring 

(a)

 in the housing inside the pump’s 

body 

(1)

. Insert the O-ring 

(b)

 in the housing on the external holed disc of the rotor 

(2)

. Position the 

rotor close to the ceramic bearing and push both inside the rotor’s house 

(Pic. V)

.

Insert the O-ring 

(c)

 in the external housing of the pump’s body 

(Pic. VI)

.

Assemble the volute 

(3)

 to the pumps’ body 

(1)

 tightening the 4 screws.

Assemble the pre-filter 

(6)

.

Summary of Contents for Syncra HF 10.0

Page 1: ...SyncraHF Instruction manual 10 0 12 0 16 0 EN DE FR I ES NL PT RU...

Page 2: ...E wire must be connected to the terminal marked N or in BLACK colour CAUTION The BROWN or BLUE leads must NEVER be connected to the earth terminal marked E or in GREEN YELLOW colour of a 3 pins plug F...

Page 3: ...SATZTEILE PIECES DE RECHANGE RICAMBI PIEZAS DE REPUESTOS Fig 2 Description Syncra HF 10 0 Syncra HF 12 0 Syncra HF 16 0 2 Rotor Shaft Rubber SGR0117 A 230V 50Hz SGR0116 A 120V 60Hz SGR0119 A 230V 50Hz...

Page 4: ...Fig 3 Fig 6 Fig 4 Fig 5 SPARE PART ROTOR KIT instruction for replacement I IV II V III VI 8 mm...

Page 5: ...p bulbs and similar 5 Always unplug an appliance from an outlet when not in use before putting on or taking off parts and before cleaning Never yank cord to pull plug from outlet Grasp the plug and pu...

Page 6: ...s accidents ne pas toucher aux pi ces mobiles ou chaudes comme les chauffe eau r flecteurs ampoules etc 5 Toujours d brancher l appareil quand il n est pas utilis quand des pi ces sont enlev es ou rem...

Page 7: ...ltage indicated on the technical data label IN LINE APPLICATIONS It is recommended to place the pump in spaces where there is a proper ventilation and the pump is not directly exposed to heat sources...

Page 8: ...nge beziehungsweise mit einem Kabel von mehr als 6 Fu L nge beim amerikanischen Typ USA geliefert werden sind diese Ger te f r den Einsatz im Au enbereich bestimmt wie von den internationalen Normen...

Page 9: ...e wieder in Betrieb zu nehmen muss der Stecker aus und wieder eingest pselt werden ACHTUNG untersch tzen Sie nicht den Kraft des Magneten Wenn Sie etwas lose den Griff und die Achse geht an den hinter...

Page 10: ...le rotor avant de rebrancher la prise pour red marrer la pompe Ch re Cliente Cher Client merci pour avoir choisi Syncra HF la pompe id ale pour la cr ation de cascades et petits ruisseaux autour de v...

Page 11: ...bicomponente 2 Rotore con girante solidale al mozzo antiusura e antirumore 3 O ring voluta filettata 1 Gas Mod 10 0 1 Gas Mod 12 0 16 0 4 Viti di serraggio voluta 4 pz 5 Coperchio posteriore pompa 6...

Page 12: ...l bloccaggio del rotore per sporco ec cessivo o altro o di funzionamento senza acqua la pompa dopo 20 tentativi di partenza si ferma automaticamente In questo caso necessario staccare la spina verific...

Page 13: ...espondiente A la que figura en la etiqueta de datos t cnicos APLICACIONES EN L NEA Se recomienda poner la bomba en espacios donde haya una ventilaci n adecuada y la bomba no est directamente expuesta...

Page 14: ...S DeSyncraHFpompenzijngeproduceerdconformdenationaleeninternationaleveiligheidsnormen Lees aandachtig en bewaar de volgende instructies om de Syncra HF optimaal te gebruiken 1 Controleer of de op het...

Page 15: ...ij volledig is ondergedompeld Afb 3 Rol de voedingskabel uit op een veilige plaats Steek de stekker in een stopcontact dat overeenkomt met dezelfde voltage die staat aangegeven op het etiket van de po...

Page 16: ...car danificado de modo algum Ligar A ficha na tomada da corrente el ctrica com tens o correspondente aquela mencionada no r tulo dos dados t cnicos APLICA ES EM LINHA recomendado colocar a bomba em es...

Page 17: ...do consumidor vigente no Brasil A garantia do produto s ser cumprida pelo revendedor ou importador no caso de apresenta o de nota fiscal comprobat ria da compra que prove que o material comprado est n...

Page 18: ...Syncra HF 3 4 5 6 Syncra HF 9 6 3 1 4 2 1 a 1 b 2 2 1 2 1 c 1 3 1 4 6 9 20 2 I II III IV a 1 2 V c VI 3 1 4 6 THE SICCE YOUTUBE www youtube com SICCEspa 2002 96 EC 2 3 5 SICCE 2 www sicce com Sicce...

Page 19: ...nuele 115 36050 Pozzoleone VI Italy Tel 39 0444 462826 Fax 39 0444 462828 P IVA VAT 02883090249 info_service sicce com www sicce com SICCE USA 1737 Louisville Drive Knoxville Tennessee 37921 USA Ph 1...

Reviews: