47(56)
5.
Trouble Shooting
5.1 Granulator Can Not Work
1. Check if the emergency stop button is reset or not.
2. Check if the feed box is closed fully, if not, or the star knob has not been
locked fully, the machine can not be started.
3. Check if the screen frame is well installed, if it doesn't closed fully or the bolt of
the safety switch isn't inserted, the machine can not be started.
4. Check the overload relay of the motor The motor equiped with overload
protector F1 in the electrical control box if the motor is overload the protector
will trip off. Trip blue button (A) eject out, press "Reset" Key (B
)
to reset. Make
sure there is no material retain in the granulator before restart the machine.
5. Check the gap between the blades If the blades are too blunt or the gap
between them is not properly, The machine will stop and the motor would be
overload, the protector will trip off. Check the blades, replace it or readjust the
gap of it, refer to chapter 5.3 for further imformations.