50(56)
4. Loosen and remove the screws of the back blades.
5. Loosen and remove the hexagon socket cap screw, remove the pressing
block and the blades ,clean the supporter box.
3) Mounting blades
Clean the fixed blades and rotating blades carefully before mounting the
blades.
Note!
Screw and washer must use new parts when changing blades each time.
Firstly mounting the fixed rear blades, then install front fixed blades,
finally install rotating blades. First of all, install the fixed blade. About the
detail assembly process, Please refer to chapter 3.5 about the mounting
description of the fixed blades and rotating blades.
6.2 Transmission
6.2.1 Daily Maintenance of V-belt
The granulator is driven by four V-belts.
1) Check the V-belt.
After 20 to 30 hours operation under full load, check V-belt tension and its
working condition. Check if the belt is wearing out every month.
2) Check V-belt tension every 6 months.
Take down the top cover on the right side of control box, pull around the belt
to see if there is any damage.
Note!
Do not put your hands between the belt and wheel, or hands crushing
may occur. Check and adjust belt tension if necessary.
Check the belt tension, (it is needed to adjust if necessary). Belt tension can be
detected by adding one force on the belt, that is to say, adding this force on the
belt between the driven pulley and driving pulley and simultaneously measure
the curve degree of belt ( this curve degree standard value is related with the
motor power and frequency, for further detail information please following table
as below.
Summary of Contents for SG-3650E
Page 1: ...SG 36E Standard Central Granulators Date Apr 2013 Version Ver A English...
Page 2: ......
Page 8: ...8 56...
Page 28: ...28 56 2 4 Wiring Diagram 2 4 1 Main Circuit Picture 2 13 Main Circuit...
Page 29: ...29 56 2 4 2 Control Circuit Picture 2 14 Control Circuit 1...
Page 30: ...30 56 Picture 2 15 Control Circuit 2...
Page 31: ...31 56 2 4 3 Electrical Components Layout Picture 2 16 Electrical Components Layout...