37(44)
if actual temperature were equal to or higher than the addition of setting
temperature value and setting value. This temperature range is between 0
and 50, and default value is 15.
4.2.5 Present Time Modification
1) Repeat the above steps until PV displays "TIME" to stand for present time.
2) Press
key to add or decrease time.
3) Press "ENTER" key and PV displays "DAY" to stand for week days.
4) Press
key to add or decrease days.
5) Press "SET" key to back to normal status after finish all the setup.
4.2.6 Weekly Time Start
1) Activate the weekly time start after finish the time setup and the present time
setup.
2) Press "AUTO" key at working or stop status to preset the time start/stop, the
"PV" will display the time and temp. alternatively.
3) Press "AUTO" again if want to cancel that weekly time setup.
4.2.7 Lock Setup Way
1) Press "SET" key down and release it till "PV" displays F-20.
2) Press
key to make "SV" to 0021, then press "ENTER" key
,
the "PV"
will display F-04.
3) F-04 are for LOCK function selection
,
press
key to select LOCK or
OFF.
4) Press ENTER or "SET" key after setup.
5) If select LOCK
,
the "SV" will display "LOCK" when pressing "SET" key, which
means the parameters have been setup and not accessible to any change.
4.2.8 The second level of Advanced Setting
1) Enter the first level of advanced setting and press
“
SET
”
and
”
Enter
”