4.2.1 Temp. Setup
1) Press the
“
SET
”
key and the LED display begins to flash, press the
key to set the temperature.
2) Press
“
ENTER
”
key to input the set value of the temperature.
4.2.2 PID Auto-tuning Setting
1) Press the
“
SET
”
key and the LED display begins to flash. Press the
“
SET
”
and
“
ENTER
”
for 1.5s and enter the Auto-tuning setting mode, at this moment
PV alternately displays
“
At
”
and present value and SV displays set value until
the Auto-tuning setting finishes. Then the system returns to the normal
operation.
2) If the Auto-tuning setting can not finish in 1 hour, the parameter will not be
changed and the system will returns to the normal operation.
3) Pressing
“
ON/OFF
”
to go back to normal operation amid automatic
calculation would not alter the original parameters.
4.2.3 Intermittent Running Setup
Drying periods
(0-ON) Stop periods (0-OFF)
1) Press "SET" key to change temp. setup value into time setup value
,
press
"TEMP/TIMER" key to enter into setup mode, at this time "SV/setup value"
flickers
,
"PV/setup value"displays"0-ON".
Picture 4-3
:
Intermittent Running Setup 1
2) PV displays "0-ON" to stand for drying periods. "0-OFF" stands for machine
stop time. Press
key to add or decrease time value of "SV/setup
→
←