5) Setup all the "ON" to 00:00 if it is not for time start/stop.
Note:
1) F-20 functions as an password lock
,
hold on "SET" till the "PV" displays F-20.
2. Press
key and only after input 0021 in the SV
,
can you press
"ENTER" to come into F-03 and other settings
,
so F-20 functions as an
coded lock for entering into next parameters setup, which prevents the
modification from nonprofessionals.
Picture 4-9
:
Weekly Time Start Setup 4
3. F-03 stands for the selection of temperature unit. Press
to shift
between
/
then press
“
℃ ℉
ENTER
”
to confirm.
4. F-04 is data lockup function, press
key to shift between OFF / LOCK,
LOCK is for locking up information
,
not able to input or change any data: OFF
is for lockup cancellation.
Picture 4-10
:
Weekly Time Start Setup 5
5. F-05 stands for the function of temperature protection. Alarm will be launched