PN-L803C/80TC3 SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 4- 4
D-SUB1
[VIDEO]
VIDEO signal
(NTSC3.58)
0.714 Vp-p
(
From Pedestal to
White
)
NTSC3.58
Full color bar (WHITE100%/ Degree of
Color saturation 100%)
*Recommended signal generator:
ASTRODESIGN Products VG-849,
VG-859
3) Display SERVICE MENU 2
4) Select "CALIBRATION" with [VOL + (
)], [VOL - (
↓
)] keys and press [ENTER] key. CALIBRATION screen appears.
5) Select "AUTO CALIBRATION" with [VOL + (
)], [VOL - (
↓
)] keys. Press [ENTER] key.
Calibration is performed and stored in EEPROM.
The adjustment result is displayed on the ADC OFFSET1/ADC OFFSET2/ADC GAIN items.
6) Select "OK" with [VOL + (
)], [VOL - (
↓
)] keys. Press [RETURN] key. CALIBRATION screen is closed.
4. FACTORY RESET
Resets the user adjustment value, USAGE TIME and the Operation log to the factory preset values.
<CAUTION>
*When resetting is made, the operation logs are also deleted. If necessary, save the operation logs before resetting.
1) Display the SERVICE MENU 2.
2) Select "FACTORY RESET" with [VOL + (
)], [VOL - (
↓
)] key, and press [ENTER] key.
3) Select "ON" with [BRIGHT - (
)],[ (
)] keys, and press [ENTER] key. "RESETTING" is displayed.
4) Turn the main power switch off and then back on.
(MEMO)
ITEM RESET
ITEMS
FACTORY RESET
Used to reset the all settings to the factory setting.
(
It includes USAGE TIME, Operation log, and Error log
)
ALL RESET 1
Used to reset the user adjustment values, the usage time, and the operation logs to the factory setting.
(
It excepts USAGE TIME, Operation log and Error log
)
ALL RESET 2
Used to reset the user setting values except the LAN settings, the communication speed, network settings,
service/support settings and SNMP settings to the factory setting.
(
It excepts USAGE TIME, Operation log and Error log
)
CALIBRATION D-SUB (ANALOG)
AUTO CALIBRATION
ADC OFFSET1
R : 999
B : 999
G : 999
ADC OFFSET2
R : 999
G : 999
B : 999
ADC GAIN
R : 999
G : 999
B : 999
OK
CANCEL
RESET
CALIBRATION SCREEN WHEN PC3/PC4 ANALOG MODE
CALIBRATION COMPONENT (D-SUB)
AUTO CALIBRATION
ADC OFFSET1
Y : 999
Cr : 999
Cb : 999
ADC OFFSET2
Y : 999
Cb : 999
Cr : 999
ADC GAIN
Y : 999
Cb : 999
Cr : 999
OK
CANCEL
RESET
CALIBRATION SCREEN WHEN AV3 COMPONENT MODE
CALIBRATION COMPONENT (D-SUB)
AUTO CALIBRATION
ADC OFFSET1
: 999
ADC OFFSET2
: 999
ADC GAIN
: 999
OK
CANCEL
RESET
CALIBRATION SCREEN WHEN AV5 VIDEO MODE
Summary of Contents for PN-80TC3
Page 183: ...PN L803C 80TC3 TROUBLESHOOTING 7 10 FUSE POSITION MAIN PWB F2200 F2300 F2102 F2302 F2101 ...
Page 184: ...PN L803C 80TC3 TROUBLESHOOTING 7 11 5V POWER SUPPLY PWB F2100 F2100 ...
Page 191: ...PN L803C 80TC3 HARDWARE DESCRIPTIONS 8 7 3 BLOCK DIAGRAM Block diagram ...
Page 202: ...PN L803C 80TC3 HARDWARE DESCRIPTIONS 8 18 5 PARTS LAYOUT Main PWB TOP ...
Page 203: ...PN L803C 80TC3 HARDWARE DESCRIPTIONS 8 19 BOTTOM ...
Page 204: ...PN L803C 80TC3 HARDWARE DESCRIPTIONS 8 20 LED Power Supply PWB TOP ...
Page 205: ...PN L803C 80TC3 HARDWARE DESCRIPTIONS 8 21 BOTTOM ...
Page 206: ...PN L803C 80TC3 HARDWARE DESCRIPTIONS 8 22 Key PWB TOP BOTTOM ...