20. TOUCH PANEL CALIBRATION TOOL
20-1. OPERATING CONDITIONS OF TOUCH PANEL CALIBRATION TOOL
The operating conditions of the touch panel calibration tool of the information display are as follows.
OS (32bit/64bit)
- Windows 8/8.1
- Windows 7
- Windows Vista
Communication port
- USB
* This tool can be used only with PN-L803C/80TBC
20-2. PC AND MONITOR SETTING
When the touch panel calibration is performed, perform the following settings for PC and the monitor.
- Set the resolution of the PC to “1920x1080”.
- Set the size of the monitor to “DotByDot”.
- When the touch panel setting tool is installed, set the Touch Operation Mode to“Multi-Touch Mode”.
- When the touch pen driver is installed, set the Input mode to “Standard” or “Pen”.
When the Input mode is set to “Pen”, perform the calibration with “Pen” mode.
20-3. START TOUCH PANEL CALIBRATION TOOL
When the touch panel calibration is performed, operate the tool as follows.
1) Click “Touch Panel Calibration” button on the Service Tool. The following screen is displayed.
Summary of Contents for PN-80TC3
Page 183: ...PN L803C 80TC3 TROUBLESHOOTING 7 10 FUSE POSITION MAIN PWB F2200 F2300 F2102 F2302 F2101 ...
Page 184: ...PN L803C 80TC3 TROUBLESHOOTING 7 11 5V POWER SUPPLY PWB F2100 F2100 ...
Page 191: ...PN L803C 80TC3 HARDWARE DESCRIPTIONS 8 7 3 BLOCK DIAGRAM Block diagram ...
Page 202: ...PN L803C 80TC3 HARDWARE DESCRIPTIONS 8 18 5 PARTS LAYOUT Main PWB TOP ...
Page 203: ...PN L803C 80TC3 HARDWARE DESCRIPTIONS 8 19 BOTTOM ...
Page 204: ...PN L803C 80TC3 HARDWARE DESCRIPTIONS 8 20 LED Power Supply PWB TOP ...
Page 205: ...PN L803C 80TC3 HARDWARE DESCRIPTIONS 8 21 BOTTOM ...
Page 206: ...PN L803C 80TC3 HARDWARE DESCRIPTIONS 8 22 Key PWB TOP BOTTOM ...