PN-L803C/80TC3 SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 4- 45
4) Click “Check” button. The window for saving the log file is displayed. Decide the saving place and the file name, and click “Save”
button. After clicking “Save” button, the sensor check starts.
<CAUTION>
- Do not touch the surface of the touch panel. The sensor check is finished after clicking “Save” button.
5) During the sensor check, “Check” button turns to “checking”. During the sensor check, do not touch the surface of the touch panel and
wait for finishing the sensor check. To finish sensor check, it will take 30 seconds to 60 seconds.
6) Confirm the check result.
<Check result>
- There is no error about the sensor.
- There are short-circuits on the displayed places.
- There are opened sensors on the displayed places.
---- Sensor Check ----
[Error] : Sensor-open detect.
- Opened sensors are displayed here.-
---- Sensor Check ----
[Error] : Sensor-short detect.
- Short-circuited places are displayed here.-
---- Sensor Check ----
OK
The default file name is
“Service_yearmonthdate_hourminutesecond.log”.
* The time is the timing when the “Check”button is clicked.
During the sensor check, “Check”
button turns to “checking”.
Check result is displayed here.
Summary of Contents for PN-80TC3
Page 183: ...PN L803C 80TC3 TROUBLESHOOTING 7 10 FUSE POSITION MAIN PWB F2200 F2300 F2102 F2302 F2101 ...
Page 184: ...PN L803C 80TC3 TROUBLESHOOTING 7 11 5V POWER SUPPLY PWB F2100 F2100 ...
Page 191: ...PN L803C 80TC3 HARDWARE DESCRIPTIONS 8 7 3 BLOCK DIAGRAM Block diagram ...
Page 202: ...PN L803C 80TC3 HARDWARE DESCRIPTIONS 8 18 5 PARTS LAYOUT Main PWB TOP ...
Page 203: ...PN L803C 80TC3 HARDWARE DESCRIPTIONS 8 19 BOTTOM ...
Page 204: ...PN L803C 80TC3 HARDWARE DESCRIPTIONS 8 20 LED Power Supply PWB TOP ...
Page 205: ...PN L803C 80TC3 HARDWARE DESCRIPTIONS 8 21 BOTTOM ...
Page 206: ...PN L803C 80TC3 HARDWARE DESCRIPTIONS 8 22 Key PWB TOP BOTTOM ...