Main code
Sub code
Content
24
14
SPF jam total counter clear
When the PRINT switch is pressed, the SPF jam total count value is reset to 0.
25
01
Main motor system ON + Cooling fan low speed (For the duplex model, the duplex motor is simultaneously
turned on.)
(Operation/Procedure)
When the START key is pressed, the main motor is rotated for 30 sec.
To save toner consumption, the different operations are executed depending on installation of the developing unit.
⋅
When the developing unit is installed, the developing bias, the main charger, and the grid are also outputted.
⋅
When the developing unit is not installed, only the motor is rotated.
∗
Do not turn on the door open/close switch forcibly to execute this simulation.
10
Polygon motor ON
(Operation/Procedure)
When the START key is pressed, the polygon motor is operated for 30sec.
26
01
Manual feed setup
(Operation/Procedure)
1. When this simulation is executed, the currently set bypass code number is displayed.
2. Enter the code number corresponding to the bypass and press the START key, and the setting will be
changed.
02
SPF setup
When this simulation is executed, the currently set SPF code number is displayed. Enter the code number of the
SPF to be set and press the PRINT switch. The setup is changed.
03
Second cassette setup
(Operation/Procedure)
1. When this simulation is executed, the currently set code number of the second cassette is displayed.
2. Enter the code number and press the start key. The setting is changed.
04
Machine duplex setup
(Operation/procedure)
1. When this simulation is executed, the currently set duplex code number is displayed.
2. Enter the code number corresponding to the duplex and press the ENTER key, and the setup will be changed.
06
Destination setup
(Operation/Procedure)
1. When this simulation is executed, the currently set destination code number is displayed.
2. Enter the code number corresponding to the destination and press the START key, and the setting will be
changed.
Code number
Bypass
0
Single bypass
1
Multi bypass
Code No.
SPF
0
Without SPF
1
With SPF (Setup is required when installing FAX.)
2
With RSPF
Code number
Second cassette
0
Without second cassette
1
With second cassette
Code number
Duplex
0
Without Duplex
1
With Duplex
Code number
Destination
0
Inch series
1
EX AB series
2
Japan AB series
AR-F152
9 – 5
Summary of Contents for AR-F152
Page 152: ...2 AR F152 13 9 ...
Page 153: ...AR F152 13 10 ...
Page 154: ...AR F152 13 11 ...
Page 155: ...AR F152 13 12 ...
Page 156: ...AR F152 13 13 ...
Page 157: ...AR F152 13 14 ...
Page 158: ...AR F152 13 15 ...
Page 159: ...AR F152 13 16 ...
Page 160: ...AR F152 13 17 ...
Page 161: ...AR F152 13 18 ...