TABLE-5: Data which is sent in the Signal send mode
MODE #
MENU (DATA)
DISPLAY
1
00000000b
1:00000000b
2
11111111b
2:11111111b
3
01010101b
3:01010101b
(5) Image memory clear mode
Procedure
LCD
Operation
1
Press FUNCTION, 9,
∗
, 8, #, 7.
DIAGNOSTIC MODE
ROM VERSION =
<version>
2
Press ENTER.
DIAGNOSTIC MODE
SELECT MENU(
←
→
)
3
Press 1, 0.
10:IMAGE MEM CLEAR
1:OK 2:CANCEL
4
Press 1.
DIAGNOSTIC MODE
SELECT MENU(
←
→
)
The image data are cleared and this mode is
terminated.
(6) Dial test / adjustment mode (Pulse 10PPS)
Procedure
LCD
Operation
1
Press FUNCTION, 9,
∗
, 8, #, 7.
DIAGNOSTIC MODE
ROM VERSION =
<version>
2
Press ENTER.
DIAGNOSTIC MODE
SELECT MENU(
←
→
)
3
Press 1, 4.
14:DIAL TEST 10 PPS
MAKE RATIO = ##%
The current make ratio setup is displayed on ##.
4
Press
←
or
→
.
(If there is no need to adjust, no need to press.)
14:DIAL TEST 10 PPS
MAKE RATIO = ##%
Press
←
to decrease by 1%.
Press
→
to increase by 1%.
5
Press ENTER.
“1590” is dialed.
6
(Adjustment/test end)
Press STOP.
This mode is terminated.
(To continue adjustment/test)
Return to 4.
(7) Dial test mode (Tone)
Procedure
LCD
Operation
1
Press FUNCTION, 9,
∗
, 8, #, 7.
DIAGNOSTIC MODE
ROM VERSION =
<version>
2
Press ENTER.
DIAGNOSTIC MODE
SELECT MENU(
←
→
)
3
Press 1, 6.
16:DIAL TEST TONE
“123456789
∗
0#” is dialed.
This mode is terminated.
(8) Print out soft switch mode
Procedure
LCD
Operation
1
Press FUNCTION, 9,
∗
, 8, #, 7.
DIAGNOSTIC MODE
ROM VERSION =
<version>
2
Press ENTER.
DIAGNOSTIC MODE
SELECT MENU(
←
→
)
3
Press 2, 1.
21:PRINT SOFT SW
The soft switch list is printed.
This mode is terminated.
AR-F152
9 – 18
Summary of Contents for AR-F152
Page 152: ...2 AR F152 13 9 ...
Page 153: ...AR F152 13 10 ...
Page 154: ...AR F152 13 11 ...
Page 155: ...AR F152 13 12 ...
Page 156: ...AR F152 13 13 ...
Page 157: ...AR F152 13 14 ...
Page 158: ...AR F152 13 15 ...
Page 159: ...AR F152 13 16 ...
Page 160: ...AR F152 13 17 ...
Page 161: ...AR F152 13 18 ...