![SEW-Eurodrive MOVIPRO SDC Manual Download Page 86](http://html.mh-extra.com/html/sew-eurodrive/movipro-sdc/movipro-sdc_manual_1250182086.webp)
86
Manual – MOVIPRO® SDC with DeviceNet Interface
10
Overview of parameters
Parameterization of MOVIPRO
®
133 / 143
Ramp t11 / t21 down CCW
0 – 2 – 2000 s
134 / 144
Ramp t12 / t22 UP = DOWN
0 – 10 – 2000 s
135 / 145
S pattern t12 / t22
0 – 3
136 / 146
Stop ramp t13/t23
0 – 2 – 20 s
137 / 147
Emergency ramp t14 / t24
0 – 2 – 20 s
139 / 149
Ramp monitoring 1 / 2
Off
16x / 17x
Fixed setpoints 1 / 2
160 / 170
Internal setpoint n11 / n21
-6000 – 150 – 6000 rpm
161 / 171
Internal setpoint n12 / n22
-6000 – 750 – 6000 rpm
162 / 172
Internal setpoint n13 / n23
-6000 – 1500 – 6000 rpm
2xx
Controller parameters
20x
Speed control
200
P gain n-controller
0.01 – 2 – 32
201
Time constant n-controller
0 – 10 – 3000 ms
202
Gain Acceleration precontrol
0 – 65
203
Filter acceleration precontrol
0 – 100 ms
204
Filter actual speed value
0 – 32 ms
205
Load precontrol CFC
-150 – 0 – 150 %
206
Sampling time n-controller
1.0 ms / 0.5 ms
207
Load precontrol VFC
-150 – 0 – 150 %
21x
Hold controller
210
P gain hold controller
0.1 – 0.5 – 32
3xx
Motor parameters
30x / 31x
Limits 1 / 2
300 / 310
Start/stop speed 1 / 2
0 – 150 rpm
301 / 311
Minimum speed 1 / 2
0 – 15. – 6100 rpm
302 / 312
Maximum speed 1 / 2
0 – 1500 – 6100 rpm
303 / 313
Current limit 1 / 2
0 – 150 % I
N
304
Torque limit
0 – 150 %
32x / 33x
Motor adjustment 1 / 2
320 / 330
Automatic adjustment 1/2
On
321 / 331
Boost 1/2
0 – 100 %
322 / 332
IxR compensation 1/2
0 – 100 %
323 / 333
Premagnetization time 1 / 2
0 – 2 s
324 / 334
Slip compensation 1 / 2
0 – 500 rpm
34x
Motor protection
340 / 342
Motor protection 1/2
Off
341 / 343
Type of cooling 1/2
Fan cooled
344
Motor protection interval
0.1 – 4 – 20 s
345 / 346
In-UL monitoring 1 / 2
0.1 – 500 A
35x
Direction of rotation of the motor
350 / 351
Direction of rotation reversal 1 / 2
Off
5xx
Monitoring functions
50x
Speed monitoring
500 / 502
Speed monitoring 1 / 2
Motor/regenerative
501 / 503
Delay time 1/2
0 – 1 – 10 s
504
Encoder monitoring motor
Off
Parameter
Name
Value
0
0
I