Check list for startup
Startup
3.2.2
Unit installation
Perform the following steps:
1. Install the components according to the information in the MOVIPRO
®
operating in-
structions:
– Supply system cable
– Motor cable
– Braking resistor
– DC 24 V backup voltage
2. Switch on all power supplies of the MOVIPRO
®
unit.
3.2.3
Configuration of MOVIPRO
®
Proceed as follows to configure the MOVIPRO
®
:
1. Start MOVITOOLS
®
MotionStudio.
2. Create a new project.
3. Set the communication properties to "Ethernet".
4. Perform a unit scan.
5. Mark the MOVIPRO
®
unit.
6. Right-click on it and select [Startup] / [Startup] from the context menu.
7. Perform a motor startup (page 78).
8. Load the respective application module into MOVIPRO
®
, if necessary.
9. Check whether the process data exchange between the controller and the
MOVIPRO
®
is working properly.
10.Enable the MOVIPRO
®
unit.
INFORMATION
For information about using MOVITOOLS
®
MotionStudio, refer to section "Operation
of MOVITOOLS
®
MotionStudio" (page 64).