![SEW-Eurodrive MOVIPRO SDC Manual Download Page 141](http://html.mh-extra.com/html/sew-eurodrive/movipro-sdc/movipro-sdc_manual_1250182141.webp)
Manual – MOVIPRO® SDC with DeviceNet Interface
141
11
MOVIPRO
®
SDC error list
Service
122
Absolute
encoder
Immediate
stop
259
SSI encoder: Insufficient clock
frequency
Set a higher cycle frequency
260
SSI encoder: Encoder signals
programmable error
Check encoder parameteriza-
tion
261
SSI encoder: No high level
present
•
Replace inverter
•
Consult SEW Service
513
EnDat encoder: Plausibility
check
514
EnDat encoder: Internal
encoder error
Replace inverter
515
516
544
576
EnDat encoder: Internal
encoder warning
Check encoder parameteriza-
tion
768
CANopen encoder: PDO time-
out
No PDO data from
CANopen encoder
•
Check interface
•
Check the configuration
769
CANopen encoder: Encoder
signals programmable error
Check encoder parameteriza-
tion
770
CANopen encoder: Change of
position
771
CANopen encoder: Emer-
gency signal
Check encoder
772
CANopen encoder: Internal
encoder error
Replace inverter
773
774
16385
HIPERFACE
®
synchronous
encoder: Plausibility check
16386
HIPERFACE
®
synchronous
encoder: Unknown encoder
type
16387
HIPERFACE
®
synchronous
encoder: Corrupt encoder
nameplate data
16417
HIPERFACE
®
synchronous
encoder: Analog voltages not
within tolerance
16418 HIPERFACE
®
synchronous
encoder: Internal encoder error
Replace inverter
16419
16420
16421
16422
16423
16424
16425 HIPERFACE
®
synchronous
encoder: Communication error
MOVIPRO
®
and
HIPERFACE
®
encoder
connection interrupted
Check wiring
16426
16427
16428
16429
Error
Suberror
Code Designation
Response (P) Code Designation
Possible cause
Measure