10
Overview of parameters
Parameterization of MOVIPRO
®
10.3 Overview of parameters
The following table shows an overview of all parameters. Factory settings are under-
lined. Numerical values are displayed with the complete setting range.
Parameter
Name
Value
0xx
Display values
00x
Process values
000
Speed
Display value
001
User display
Display value
002
Frequency
Display value
003
Actual position
Display value
004
Output current
Display value
005
Active current
Display value
006 / 007
Motor utilization 1 / 2
Display value
008
DC link voltage
Display value
009
Output current
Display value
01x
Status displays
010
Inverter status
Display value
011
Operating status
Display value
012
Error status
Display value
013
Current parameter set
Display value
014
Heat sink temperature
Display value
015
Operating hours
Display value
016
Enable hours
Display value
017
Work
Display value
018 / 019
KTY utilization 1 / 2
Display value
02x
Analog setpoints
020
Analog input AI1
Display value
03x
Binary inputs of basic unit
030
Binary input DIØØ
Display value
032 – 035
Binary inputs DIØ2 – DIØ5
Display value
05x
Binary outputs of basic unit
050
Binary output DBØØ
Display value
07x
Unit data
070
Unit type
Display value
071
Rated output current
Display value
072
Encoder slot option/firmware
Display value
076
Basic unit firmware
Display value
078
Technology function
Display value
079
Unit type
Display value
08x
Error memory
080 – 084
Fault t-0 – t-4
Display value
094 – 096
PO1 – PO3 setpoint
Display value
097 – 099
PI1 – PI3 actual value
Display value
1xx
Setpoints/ramp generators
13x / 14x
Speed ramps 1 / 2
130 / 140
Ramp t11 / t21up CW
0 – 2 – 2000 s
131 / 141
Ramp t11 / t21 down CW
0 – 2 – 2000 s
132 / 142
Ramp t11 / t21up CCW
0 – 2 – 2000 s
0
0
I