Manual – MOVIPRO® SDC with DeviceNet Interface
135
11
MOVIPRO
®
SDC error list
Service
25
EEPROM
Rapid stop
0
Read or write error on
EEPROM power section
Error while accessing
EEPROM
•
Restore factory settings,
perform reset and reset
parameters.
•
Consult SEW service if the
error reoccurs
11
NV memory read error
Internal NVRAM
13
NV memory chip card
System module defective
14
NV memory chip card
Memory card defective
16
NV memory initialization error
26
External termi-
nal
Emergency
stop (P)
0
External terminal
Read external error sig-
nal via programmable
input
Eliminate respective cause;
reprogram terminal if necessary
27
No limit
switches
Emergency
stop
0
Both limit switches missing or
open circuit
•
Open circuit/both
limit switches
missing
•
Limit switches are
swapped over in
relation to direction
of rotation of motor
•
Check wiring of limit
switches
•
Swap limit switch
connections
•
Reprogram terminals
2
Limit switch reversed
3
Both limit switches are active
simultaneously
29
Limit switch
contacted
Emergency
stop
0
Hardware limit switch
approached
A limit switch has been
reached in IPOS
plus®
mode (only with appli-
cation module).
•
Check travel range
•
Correct operator program
30
Emergency
stop
Timeout
Immediate dis-
connection
0
Emergency stop ramp time
exceeded
•
Drive overloaded
•
Emergency stop
ramp too short
•
Check configuration
•
Extend emergency stop
ramp
31
TF/TH sensor
tripped
No response
(P)
0
Thermal motor protection error •
Motor too hot, TF/
TH has triggered
•
TF/TH of the motor
not connected or
connected
incorrectly
•
MOVIDRIVE
®
connection and TF/
TH connection on
motor interrupted
•
Let motor cool off and reset
error
•
Check connections/link
between MOVIDRIVE
®
and
TF/TH.
•
Set P835 to "No response"
32
IPOS index
overflow
Emergency
stop
0
IPOS
plus®
program is faulty
Programming princi-
ples violated leading to
system-internal stack
overflow
Reload the application module
34
Ramp
Timeout
Immediate dis-
connection
0
Rapid stop ramp timeout
Downward ramps time-
out, e.g. due to over-
load.
•
Extend the downwards
ramps
•
Eliminate overload
35
Operating
mode
Immediate dis-
connection
0
Operating mode not available Operating mode not
defined or defined
incorrectly
Use P700/P701 to set correct
operating mode
1
Wrong assignment operating
mode - hardware
37
System watch-
dog
Immediate dis-
connection
0
"System watchdog overflow"
error
Error while executing
system software
Consult SEW Service
38
System soft-
ware
Immediate dis-
connection
0
"System software" error
System malfunction
Consult SEW Service
39
Reference
travel
Immediate dis-
connection (P)
0
"Reference travel" error
•
The reference cam
is missing or does
not switch
•
Limit switches are
connected
incorrectly
•
Reference travel
type was changed
during reference
travel
•
Check reference cam
•
Check limit switch
connection
•
Check reference travel type
setting and required
parameters.
40
Boot synchro-
nization
Immediate dis-
connection
0
Timeout during boot synchroni-
zation
Error during boot syn-
chronization between
inverter and option.
Consult SEW service if the
error reoccurs
Error
Suberror
Code Designation
Response (P) Code Designation
Possible cause