6
Operating modes and limit values
Safe operation of category 2 motors on inverters
Operating Instructions – EDR..71 – 315, EDRN63 – 315
99
EDR.. motors in
m
connection at a motor voltage of 230/400 V, 2G, 2GD
Motors
P
N
I
N
n
max
Inverter power
kW
A
min
-1
kW
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3
4
5.5
7.5
11
15
EDRS71S4
0.25
1.35
2510
o
x
o
o
–
–
–
–
–
–
–
–
–
EDRS71M4
0.37
2.1
2465
–
o
o
x
o
o
–
–
–
–
–
–
–
EDRS80S4
0.55
2.4
2525
–
–
o
x
o
o
–
–
–
–
–
–
–
EDRE80M4
0.5
2.4
2540
–
–
o
x
o
o
–
–
–
–
–
–
–
EDRE80M4
0.75
3.1
2535
–
–
–
o
o
x
o
–
–
–
–
–
–
EDRE90M4
1.1
4.4
2530
–
–
–
–
o
o
x
o
–
–
–
–
–
EDRE90L4
1.5
6
2535
–
–
–
–
–
–
o
x
o
–
–
–
–
EDRE100M4
2.2
8.5
2530
–
–
–
–
–
–
–
o
x
o
o
–
–
EDRE100L4
2.2
9
2540
–
–
–
–
–
–
–
o
x
o
o
–
–
EDRE100LC4
3
11.1
2555
–
–
–
–
–
–
–
–
o
x
o
–
–
EDRE112M4
3
11.1
1740
–
–
–
–
–
–
–
–
o
x
o
–
–
EDRE132S4
4
14
1760
–
–
–
–
–
–
–
–
–
o
x
o
–
EDRE132M4
5.5
19.9
1730
–
–
–
–
–
–
–
–
–
–
o
x
o
Motors
P
N
I
N
n
max
Inverter power
kW
A
min
-1
kW
11
15
22
30
37
45
55
75
90
110
EDRE160S4
7.5
26.6
1750
o
x
o
–
–
–
–
–
–
–
EDRE160M4
9.2
34.6
1760
–
o
x
o
–
–
–
–
–
–
EDRE180S4
11
38
2340
–
o
x
o
o
–
–
–
–
–
EDRE180M4
15
51
2330
–
–
o
x
o
o
–
–
–
–
EDRE180L4
18.5
62.3
2340
–
–
o
o
x
o
o
–
–
–
EDRE200L4
22
77.9
2375
–
–
–
o
o
x
o
o
–
–
EDRE225S4
30
101.2
2375
–
–
–
–
o
o
x
o
o
o
EDRE225M4
37
123.7
2075
–
–
–
–
–
o
o
x
o
o
x
= recommended
o
= permitted
–
= not permitted