Operating Instructions – EDR..71 – 315, EDRN63 – 315
88
5.17.4
Temperature sensor /PT (PT100)
NOTICE
Excessive self-heating of the temperature detection can damage the insulation of
the temperature detection as well as the motor winding.
The drive system might be damaged.
•
Avoid currents > 3 mA in the circuit of the PT100.
•
Observe the correct connection of the PT100 to ensure correct evaluation of the
temperature detection.
The characteristic curve in the following figure shows the resistance curve subject to
the motor temperature.
0
50
100
150
200
250
300
-100
-50
0
50
100
150
200
250
T [°C]
R [
Ω
]
1145838347
Technical data
PT100
Connection
Red/white
Resistance at 20 – 25 °C per PT100
107.8 Ω < R < 109.7 Ω
Test current
< 3 mA
5.17.5
Forced cooling fan /VE
Motors can be equipped with a forced cooling fan as an option. For information on
connection and safe operation, refer to chapter "Operation and maintenance instruc-
tions for forced cooling fan /VE".