Section 5
Before Calling for Service
Part Number 020003999 6/14
5-3
Pump Troubleshooting
Selectable Ice Troubleshooting
Problem
Possible Cause
Corrective Action
Pump motor does not
shut off
Problem with probe or probe harness
Pump motor
intermittent
Problem with probe or probe harness
Pump motor does not
pump
Water pressure from water source is not
high enough
Verify water pressure leading into pump inlet is 40 psi
minimum.
Problem
Possible Cause
To Correct
DISPENSER DOES NOT DISPENSE
CRUSHED ICE
Nothing is heard
No power
Check power source and power cord.
Loose wire in electrical system
Check wiring.
Dispense switch faulty
Replace switch.
Crusher motor faulty
Replace motor/gear box.
Dispenser safety switch open
Assure merchandiser is installed
correctly with the safety switch in the
closed position.
Crusher motor hums but does not turn
Blades obstructed
Check for obstructions in ice crusher
housing.
Motor faulty
Replace motor.
Faulty start relay/capacitor
Check relay/capacitor and replace if bad.
Crusher dispense door does not open
Door solenoid faulty
Replace solenoid.
Loose wiring to solenoid
Check wiring.
Gear box on motor
Gear box on motor faulty
Replace ice crusher motor assembly.
Crusher axle broken
Replace crusher axle.
Crusher motor turns but gear motor for
paddle wheel/agitator bar does not turn
Agitator gear motor faulty
Replace agitator gear motor.
Loose wiring
Check wiring.
Obstruction in Ice bin stopping motor
Check for obstruction.
Nothing on dispenser works
No power to dispenser
Check power source.
Dispenser safety switch opens
Assure merchandiser is installed
correctly with the safety switch in the
closed position.
Loose wiring
Check wiring.
Difficulty inserting blade/hub assembly
into crusher housing
a. Stationary blades not aligned with
locating slots at top and bottom of
crusher housing
See “Disassemble the Ice Crusher
Assembly” section in this manual.
b. Rotating blades not in vertical position
c. Check for ice in crusher housing
Crushed ice dispenses continuously, or
by itself
Ice dispense switch faulty
Adjust bridge in ice machine or, when
manually filling, break up clusters.
No flashing lights on keypad –
Fluorescent light was on, crusher and
whole ice dispenser will not function,
transformer breaker blown
Water shorted out wiring harness on
valves only
Clean up water and reset transformer.
1. Remove probe electronics.
2. Pass magnetic tip of screwdriver by
lower end of tube extending from
electronics package.
3. Reed switch will close.
4. Carbonator operates.