FP400 components
FP400 Product Guide
Page 9
FP400 components
FP400 Processor
The FP400 processor operates on 12 to 48 VDC input power, or can be powered by PoE, and
consumes 2 W (nominal).
Relay outputs
The FP400 processor has 6 user-configurable Form C relay outputs rated for 30 V @ 1 A max.
When the processor is set to Local control mode, the relays are used to signal alarm and
supervision conditions. For network based processors (set to Remote control mode) alarm data is
carried over the network cables and the six relays are available as output control points from the
security management system.
Auxiliary inputs
The processor includes 2 voltage sensing self-test/auxiliary device inputs. In Local control mode
the inputs are used to activate electronic self-tests. In Remote control mode the inputs are used to
report the status of 1 or 2 auxiliary security devices to the host SMS.
Figure 2 FP400 processor connections
USB port for UCM
2 voltage sensing auxiliary device/self-test inputs
6 Form C relay outputs
DC input
front
rear
or PoE
option card mounting
Zone 1
receive
Zone 4
receive
Zone 2
receive
Zone 3
receive
Zone 1
Zone 4
Zone 2
Zone 3
transmit transmit transmit transmit
setup and configuration
system activity LEDs
panel
panel