FP400 installation overview
Page 22
FP400 Product Guide
Optical fiber safety
Fiber optic cable handling
Sensor cable performance specifications
The following manufacturer’s performance specifications apply to the sensor cable:
•
Fiber count 12 fibers 1 tube
•
Fiber type 9/125 single-mode
•
Manufacturer’s maximum cable attenuation 0.24 dB/km @ 1550 nm
•
Minimum allowable bend radius (dynamic) 12 cm (5 in.) (20 X OD)
•
Minimum allowable bend radius (static) 6 cm (2.5 in.) (10 X OD)
•
Maximum allowable tensile rating during installation 800 N (180 lbf)
•
Maximum allowable tensile rating installed 400 N (90 lbf)
•
Crush resistance (short term) 1000 N (740 lbf)
•
Temperature ratings (operational/storage) -40 to 70ºC (-40 to 158º F)
•
Temperature ratings (installation) -10 to 60ºC (14 to 140º F)
•
Typical outside diameter 6 mm (0.25 in.)
Additional cable requirements
•
FRP strength members
•
water blocking tube
•
gel filled buffer tube
•
cable OD 6.0 mm
•
HDPE outer jacket
Cable loss limits (maximum attenuation)
•
Average loss over the full length of installed cable < 0.3 dB/km (< 0.48 dB/mi.)
•
Individual event loss limit < 0.1 dB
WARNING
Use care when working with exposed optical fibers. The bare fibers are
125 microns in diameter and can easily penetrate skin.
Always wear safety glasses when working with optical fibers.
Always dispose of bare fibers in a sealed and labeled container that is
specifically designed to contain fiber optic waste.
NEVER dispose of bare fibers in a standard waste receptacle.
Note
The sensor cable (p/n F4SP0101) includes 12 optical fibers inside a gel
filled buffer tube. Custom sized cables are also available with additional
fibers (contact Senstar for details).
Note
Fusion splice performance typically results in a loss of between 0.01 and
0.03 dB.