![Sena Parani10 User Manual Download Page 42](http://html1.mh-extra.com/html/sena/parani10/parani10_user-manual_1237624042.webp)
42
Appendix C: Troubleshooting
C.1 ON/OFF of Hardware Flow Control
Parani10 is designed to use CTS/RTS for handshaking. For equipment that is not using
Hardware flow control for serial communications, Parani10’s firmware should be set to turn OFF
hardware flow control (CTS/RTS).
Customers may indicate preferences when ordering or turn off the handshaking by bridging CTS
and RTS (no. 7 and no. 8 lines) using a Gender changer.
Parani10 has automatic detection feature of hardware flow control, but in certain environment
such as PC, this function may not operate correctly.
*
C
ustomers may choose the usage of hardware flow control using Parani10_Manager
software.
If checked, Parani10 will use hardware flow control. If you do not want to use the function,
please uncheck and press Apply button.