![Sena Parani10 User Manual Download Page 34](http://html1.mh-extra.com/html/sena/parani10/parani10_user-manual_1237624034.webp)
34
module.
3)
AT&F<cr>
<cr><lf>OK<cr><lf>
Reset to factory default state
4)
AT+BTINQ?<cr>
<cr><lf>112233445
5,FriendlyName,Co
D<cr><lf>
<cr><lf>112233445
5,FriendlyName,Co
D<cr><lf>
<cr><lf>112233445
5,FriendlyName,Co
D<cr><lf>
<cr><lf>OK<cr><lf>
Inquiry nearby devices. The OK at
the end means end of inquiry.
5)
ATD112233445566<cr>
<cr><lf>OK<cr><lf>
<cr><lf>CONNECT
<cr><lf> or
<cr><lf>ERROR<cr
><lf>
Connect to the specified device.
If you want to enable Authentication
and Encryption, just set variable as 1.
6)
ATD<cr>
<cr><lf>OK<cr><lf>
<cr><lf>CONNECT
<cr><lf> or
<cr><lf>ERROR<cr
><lf>
Connect to the device that last
successfully connected.
7)
AT+BTSCAN<cr>
<cr><lf>OK<cr><lf>
Enable inquiry and page scans with
timeout of infinity.
8)
AT+BTSCAN,n,to<cr>
<cr><lf>OK<cr><lf>
Enable inquiry or Page scans.
If n=1, disable page and enable
inquiry.
If n=2, enable page and disable
inquiry.
If n=3, enable both page and inquiry.
Scan will be performed during <to>
seconds.
9)
AT+BTSCAN112233445566,to<cr>
<cr><lf>OK<cr><lf>
Will scan of only specified device.
10)
AT+BTCANCEL<cr>
<cr><lf>OK<cr><lf>
cancel the current pending operation
when the device is inquiring, paging
Summary of Contents for Parani10