![Sena Parani10 User Manual Download Page 37](http://html1.mh-extra.com/html/sena/parani10/parani10_user-manual_1237624037.webp)
37
S-register command: If you change the values of S-register, please reboot Parani10.
ATSnn=mm<cr>: To change ATSnn register value
ATSnn?: To check current ATSnn register value.
29)
ATS3
Stream UART policy (Default 0)
If set as ‘0’, throughput is the priority, if set as ‘1’, Latency
is the priority.
30)
ATS4
Enable Remote name query (default 1)
Get BDaddress and device name during Inquiry.
If set as ‘0’, only get BD address. Inquiry time can be
faster.
31)
ATS10
Default 1
ATS10=1<cr> :
Enabling all of the response messages- OK, CONNECT,
DISCONNECT, and ERROR.
ATS10=0<cr> :
Disabling all of the response messages- OK, CONNECT,
DISCONNECT, and ERROR.
ATS10?<cr> : To see current status of ATS10
32)
ATS11
Enable Escape (default 1)
Escape sequence character enable change from on-line
mode to command mode. If set to ‘0’, transmission speed
can be improved.
33)
ATS12
Clear UART buffer at Disconnect. (default 0)
If set to ‘1’, when disconnected, data stored in Parani10
will be removed.
34)
ATS13
Enable CDC accept (default 0)
If set to ‘0’, Parani10 will use CDC signal to let Host know
Bluetooth connection status.
If set to ‘1’, Parani10 will accept CDC signal from other
peer (DCE-configured) Bluetooth device.
35)
ATS14
ATS14=1<cr>: Users may use DTR/DSR lines for
communications
ATS14=0<cr>: Users may use DTR/DSR lines for Loop-
back only.
Default value of ATS14 is 0.
Summary of Contents for Parani10
Page 1: ...1 Parani10 Enabling Wireless Serial Communication Users Guide Version 1 0 0 2005 03 07...
Page 3: ...3 Revision History Revision Date Name Description V1 0 0 2005 03 02 D H Shin Initial Release...
Page 7: ...7 Fig 1 2 1 DC Power Cable Red colored wire of DC power cable is for...
Page 41: ...41 HIGHT 35 mm 3 2 OUTPUT CABLE CABLE LENGTH 1850 50...