![Sena Parani10 User Manual Download Page 40](http://html1.mh-extra.com/html/sena/parani10/parani10_user-manual_1237624040.webp)
40
2.2.1.1. Specified output regulation limit includes line regulation and load regulation.
2.2.1.2. Continuous output shall not exceed 10 W.
2.2.1.3. Ripple and noise is measured at the end of output connector with 20MHz oscilloscope
bandwidth.
2.2.1.4. A 22uF Electrolytic capacitor and a 0.22uF Ceramic capacitor should be connected in
parallel with output load..
2.2.2.
EFFICINCY : Minimum 70 % at 2A load condition.
2.2.3.
SHORT CIRCUIT PROTECTION : CYCLING
2.2.4.
NO LOAD OPERATION : NO DAMAGE
2.2.5.
DI-ELECTRIC WITHSTANDING VOLTAGE
2.2.5.1. Primary to Secondary : 3 KV, 1 Second
2.2.5.2. Cut-Off Current : 10mA
2.2.6.
EMI
2.2.6.1. Shall be designed to meet CLASS B Limit of FCC part 15.
2.2.6.2. Shall be designed to meet EN 55022
2.2.7.
SAFETY
2.2.7.1. UL & cUL : UL1950
2.2.7.2. TUV - CE : EN60950
2.2.7.3. ek-mark : K60950
2.2.7.4. CB / QAS / CCIB / PSE
2.3.
GENERAL CHARACTERISTICS
2.3.1.
OPERATING TEMPERATURE RANGE: 0’C to 35’C at 100% Load condition.
0’C to 40’C at 90% Load condition.
2.3.2.
OPERATING HUMIDITY: 15 to 80% RELATIVE HUMIDITY
2.3.3.
STORAGE TEMPERATURE: -20’C to 85’C
2.3.4.
STORAGE HUMIDITY: 90 % RELATIVE
2.3.5.
BURN-IN PROCESS
2.3.5.1. All unit shall be subjected to burn-in process of mass production.
2.3.5.2. TEMPERATURE: 30 +/-5’C
2.3.5.3. LOAD CONDITION: 2 A
2.3.5.4. INPUT VOLTAGE: 110 / 220 Vac
3.
MECHANICAL CHARACTERISTICS
3.1.
DIMENSIONAL SIZE
LENGTH: 66 mm
WIDTH: 48.5 mm
Summary of Contents for Parani10
Page 1: ...1 Parani10 Enabling Wireless Serial Communication Users Guide Version 1 0 0 2005 03 07...
Page 3: ...3 Revision History Revision Date Name Description V1 0 0 2005 03 02 D H Shin Initial Release...
Page 7: ...7 Fig 1 2 1 DC Power Cable Red colored wire of DC power cable is for...
Page 41: ...41 HIGHT 35 mm 3 2 OUTPUT CABLE CABLE LENGTH 1850 50...