Function
Code
Parameter
Name
Setting Range
Default
Prope-
rty
Modbus
Address
Input terminal
filter time
P4-10
0.000s
〜
1.000s
0.010
Terminal
command
mode
0
Terminal
UP/DOWN
rate of
change
0.001Hz/s
〜
65.535Hz/s
1.00Hz/s
AI Curve
1 minimum
input
0.00V
〜
P4-15
0.00V
AI Curve 1
minimum
input
corresponding
value
-100.0%
〜
+100.0%
0.0%
AI Curve 1
maximum input
P4-13
〜
+10.00V
10.00V
AI Curve 1
maximum
input
corresponding
value
-100.0%
〜
+100.0%
100.0%
AI1 Filtering
time
0.00s
〜
10.00s
0.10s
AI Curve 2
minimum input
0.00V
〜
P4-20
0.00V
AI Curve 2
minimum
input
corresponding
value
-100.0%
〜
+100.0%
0.0%
AI Curve 2
maximum input
P4-18
〜
+10.00V
10.00V
○
P4-11
●
0: Two-wire mode 1
1: Two-wire mode 2
2: Three-wire mode 1
3: Three-wire mode 2
P4-12
●
P4-13
Fun-
ction
Code
Parameter
Name
Setting range
Default
Prope-
rty
Modbus
Address
○
P4-14
○
P4-15
○
P4-16
○
P4-17
○
P4-18
○
P4-19
○
P4-20
○
User Manual
Chapter 5
User Manual
Chapter 5
0
17 : Acceleration/deceleration
time selection 2
18 : Frequency source switchover
19 : Keyboard UP/DOWN setting
is cleared (terminal\keyboard)
20 : Command source switchover
terminal
21 : Acceleration/deceleration
prohibition
22 : PID pause 23 : PLC reset
24 : swing frequency pause
25 : counter input
26 : Counter reset
27 : Length count input
28 : Length reset
29 : Torque control prohibited
30 : Pulse frequency input
32 : Immediate DC braking
33 : Normally closed (NC)
input of external fault
34 : If this terminal is valid,
frequency modification is allowed;
if The terminal status is invalid, &
frequency modification is
prohibited.
35 : PID action direction is
reversed
36 : External STOP terminal 1
37 : Command source
switchover terminal 2
38 : PID integral pause
39 : Switchover between main
frequency source X and preset
frequency
40 : Switchover between
auxiliary frequency source Y
and preset frequency
43 : PID parameter switchover
44 : User-defined fault 1
45 : User-defined fault 2
46 : Speed control/Torque
control switchover
47 : Emergency stop
48 : External STOP terminal 2
49 : Deceleration DC braking
50 : Clear the current running
time
13
P4-04
X6 Terminal
function
selection
●
P4-05
X5 Terminal
function
selection
●
0
P4-06
X7 Terminal
function
selection
●
0
P4-07
X8 Terminal
function
selection
●
0
P4-08
X9 Terminal
function
selection
●
62469
62470
62471
62472
62473
62475
62476
62477
62478
62479
62480
62481
62482
62483
62484
62485
51 : Switchover between two-
line mode and three-line mode
52 : Reverse rotation is
prohibited