ProLogic L22
Operation Instructions
6
The ProLogic L22 has a Duress Feature, which allows a User or Admin to open the lock and send a silent
Duress signal indicating that you are in danger. By default, the duress function is active and cannot be
disabled.
In Order to send a signal, the system must have a CB10 junction box installed and must be connected to
an alarm panel.
To Open the Lock under Duress:
Step 1: Enter a valid Code, but add or subtract 1 from the code. The Lock will open as normal and a
silent alarm will be issued.
Note: This will be logged as “Duress Unlock” in events.
For example, if your code is 123456; under Duress, enter 123455 or 123457 to send silent alarm.
Note: The ProLogic L22 has a function called “Duress Code Shift”. This function allows you to specify
the number to be added or subtracted from the code during a duress entry. See Section C - 11.0.
2.4 Opening the Lock in Dual Control
The ProLogic L22 can be programmed so that two User codes are required to open the lock. This
function is called “Enable Dual Mode”, See 8.1
To Open a Lock under Dual Control:
Step 1: Enter User code
The display will read “IDXX Verified”.
For example, ID03 will display “ID03 Verified”.
The display will then read:
“Enter 2
nd
User Code”
For example, using ID04 for 2
nd
code will read “ID04 Verified”.
The lock will open and relock in 6 seconds.