1.0 System Installation
1.1 System Components
The system consists of (1) EntryPad – Part # EC-0601A-L22 plus (1) or more Lock bodies as follows:
SwingBolt – Part # EL-0601
SwingBolt with Status – Part # EL-0601-S
DeadBolt – Part # EL-0701
SpringBolt – Part #EL-0801
StrikeBolt – Part #EL-0901
Note: The ProLogic L22 can control up to 4 locks when used in conjunction with the Expansion Box –
Part # CB11-1T4. (If setting up a multi-lock system, please refer to Section 10.2 – Multi-Lock Systems)
1.2 Pairing the EntryPad and the Lock
SECURAM safe lock systems can operate in two different modes depending upon the type of EntryPad
being used with the lock body. The ProLogic L22 is a digital lock system and therefore the lock must also
be programmed in digital mode. Both modes follow the same steps to reset / set which is done by
following the steps detailed below:
Step 1: Ensure the battery is disconnected from the Entry Pad.
Step 2: Ensure the lock cable is disconnected from the lock body.
Step 3: Locate the Reset Hole on the back of the lock (under the QC sticker).
Step 4: Using a paper clip depress the reset button, inside the reset hole, 3 times to dissipate
any latent energy in the lock.
Step 5: Now depress the reset button and hold.
Step 6: While continuing to depress the reset button, connect the lock cable to the lock body.
Step 7: While continuing to depress the reset button, connect the 9V battery to the EntryPad
terminals.
Step 8: Continue to hold down the reset button for 5 seconds and then release.
Step 9: Verify that the pairing has been completed, by opening the lock with the default code
111111.
Step 10: Press any button on the EntryPad to initiate a lock communication test. The EntryPad
will display system information followed by: