ProLogic L22
Operation Instructions
18
Step 5: Press OK.
Dual Mode has now been enabled. Two valid codes will be required to open the safe lock system.
ID00, ID01 and ID02 are Dual Mode Override Codes.
**Note to Disable Dual Mode: When Dual Mode is enabled this Menu Selection will change to
Disable Dual Mode. Therefore to Disable Dual Mode, follow the steps above.
9.0 Door Management
9.1 Max. Door Open Time
This menu selection allows you to set the length of time a door can be opened.
Step1: Press the Menu/OK button.
Step 2: Using the
and
, scroll to the System Menu and Press OK.
Step 3: The display will prompt you to enter a valid code. Enter either the Super Code (ID00) or
the Manager Code (ID01). The “Select Menu” message will be displayed as follows:
Step 4: Scroll
to the menu selection “Max. Door Open Time” and Press OK.
Step 5: You will be prompted to enter the maximum length of time the door can be opened.,
after which the LCD will report an alert indicating that the door opening has exceeded the
allowable time limit,- the lock sound with an audible beep.
9.2 Configuring a Multi-Lock system
The ProLogic L22 is capable of managing 4 locks. A CB11-1T4 is required to operate 4 locks with the
ProLogic L22 EntryPad. In order to manage more than one lock, you need to tell the system how many
locks are connected, and then identify the locks with a number. Users can then be assigned access
rights to open specific locks.
9.3 Set Number of Locks
Step1: Press the Menu/OK button.
Step 2: Using the
and
, scroll to the System Menu and Press OK.