Programming the Wrong-Code Lockout/Alarm:
The device can be programmed to either lockout (deny access) or sound an alarm after 10
successive wrong user codes or fingerprints. The lockout will continue and the LED will flash red
for 10 minutes and cannot be reset until the time is expired. The keypad sounds and/or external
alarm will sound (depending on your settings for them), but can be stopped with a valid master
code, user code, or fingerprint (see "Programming the Keypad Sounds/Notifications," pgs. 18~19
and "Programming the External Alarm Output," pg. 19).
When programming the wrong code lockout, use the following general formula from within base
programming mode (see "Enter and Exit Base Programming Mode," pg. 9):
– Program Wrong-Code Lockout function code (LED will change to steady orange)
–Disable or Enable/Configure the Wrong-Code Lockout/Alarm
Disable or Enable/Configure Wrong-Code Lockout:
•
– Disable wrong-code lockout (factory default)
•
– Enable wrong-code lockout to deny access for 10 minutes
•
– Enable wrong-code alarm to sound the keypad notifications / external alarm
NOTES:
•
If wrong-code lockout is enabled, the LED will flash red and all access will be denied for 10
minutes after 10 successive wrong codes/fingerprints.
•
If wrong-code alarm is enabled, the LED will flash and keypad notifications and/or external
alarm will sound and continue for the length of time programmed for the external alarm or until
a valid master code, user code, or user fingerprint is entered. This setting requires the keypad
notifications and/or external alarm to be enabled.
•
The
key returns you to base programming mode (the LED will flash red). To program other
functions, press the function number for that function (LED becomes steady orange).
•
Exit programming mode by pressing the
key after all programming is completed. One beep
will sound and the LED will return to steady red. After 25 seconds of inactivity, the keypad will
automatically exit programming mode and return to standby.
Examples:
1.
Disable the wrong-code lockout:
2.
Enable the
wrong-code lockout to deny access for 10 minutes:
3.
Enable the
wrong-code lockout to deny access until a valid master code, user code, or user
fingerprint is entered: