Programming User Fingerprints (Continued):
NOTES:
•
The add user function key places you into this programming mode. Press the add user function
key
only before adding the first user. To continue to add other users in the same session,
do not repeat the add user function code
.
•
represents the user fingerprint, which must be presented twice. The unit will beep once
and the LED will flash green once to indicate that the fingerprints were read successfully.
With Master Add Fingerprint:
Using the master add fingerprint allows the programmer to quickly add user fingerprints without
going into programming mode, particularly useful when adding a single user fingerprint (see
"Programming the Master Add/Delete Fingerprints," pgs. 9~10). The fingerprint will be assigned to
the first available fingerprint user ID in numerical order (IDs 1~998).
– Master Add fingerprint. The device will beep once, the green LED will flash once, then
change to steady orange.
– User’s fingerprint
Examples Using the Master Add Fingerprint:
1.
Program a user fingerprint for single user using the master add fingerprint:
2.
Program user fingerprints for two users using the master add fingerprint:
(1
st
user) wait for beep, then
(2
nd
user)
NOTES:
•
represents the user fingerprint, which must be presented twice. The unit will beep once
and the LED will flash green once to indicate that the fingerprints were read successfully.
•
Exit programming mode by presenting the master add fingerprint twice or by pressing the
key after all programming is completed. One beep will sound and the LED will return to steady
red. After 25 seconds of inactivity, the keypad will automatically exit programming mode and
return to standby.
•